{"product_id":"digital-led-temperature-controller-w3230-high-precision-thermostat-with-probe-for-heating-and-cooling-dc-12v-24v-ac-110-220v","title":"Digital LED Temperature Controller W3230 High-Precision Thermostat with Probe for Heating and Cooling, DC 12V¨C24V AC 110¨C220V","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eApplication\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eComputer\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eKeszoox\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCondition\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNew\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCutting Size\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e73mm*39mm\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eDissipation Power\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e1\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e-55¡æ-120¡æ\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePackage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eDIP\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eQuantity\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e1\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eSIZE\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e79mm*43mm\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eSensor wire\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e1 meter\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eDC 12V\/ AC 110V-220V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eVoltage Regulator\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eWEIGHT\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e45G\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eInformation:\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eSIZE£º79mm*43mm\u003cbr\u003eWEIGHT£º45G\u003cbr\u003ePower Supply:DC 12V\/ AC 110V-220V\u003cbr\u003e12V\/120W    24V\/240W    110V-220V\/1500W\u003cbr\u003eTemperature Control Range:-55¡æ-120¡æ\u003cbr\u003eResolution Ratio: 0.1¡ãC(-9.9-99.9); 1¡ãC(other range)\u003cbr\u003eColor of Displaying: red\/blue\u003cbr\u003eMeasurement accuracy: ¡À0.1¡ãC\u003cbr\u003eControl accuracy: 0.1¡ãC\u003cbr\u003eSensor: NTC10K Waterproof sensor\u003cbr\u003eOutput: Relay Contact Capacity 20A 12V \/ 10A 220V\u003cbr\u003eEnvironmental requirements: -10-60¡ãC , humidity 20%-85%RH\u003cbr\u003eDimension:79mm *43mm*26mm\u003cbr\u003eCutting Size:73mm*39mm\u003cbr\u003eSensor wire: 1 meter\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sc266b5bc5c70443c9c3deca99dcf4c9cn.png\" slate-data-type=\"image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/S15d99c4297684ab1ae4e440fa8cc2f27x.png\" slate-data-type=\"image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sf0ff2476526a4f8da66e2b255c3b7ed1g.png\" slate-data-type=\"image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/S8c866353a5ce4aebbe89c2e0f34d3238j.png\" slate-data-type=\"image\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eHow to save settings\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eIf you want to save the set data,set P7 to ON when the temperature is set and the power is off. In this case,the last setting will be retained when the power is turned off.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eReset\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eDue to some human reasons,the internal setting of the thermostat is confusing. It takes a lot of time to set the time. In this case,you can use this function to restore the factory settings. In the off state,press and hold the + and - buttons simultaneously.,then power on,all the above parameters are restored to the factory settings.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eFunction description:\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eP0: refrigeration or heating mode\u003cbr\u003e\u003cbr\u003eP1: return difference setting\u003cbr\u003e\u003cbr\u003eP2: maximum temperature setting upper limit\u003cbr\u003e\u003cbr\u003eP3: minimum temperature setting lower limit\u003cbr\u003e\u003cbr\u003eP4: temperature correction\u003cbr\u003e\u003cbr\u003eP5: delay start time (unit: minute)\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eMethod of Use\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eAt this time, the display is displayed as measuring temperature. Press the SET key once and the display temperature flashes. Press +- to SET the required temperature (+- can quickly rise and fall) After the setting is complete, press Set to confirm and return. The output of the thermostat is 20A relay, which can meet various high-power loads. If the control circuit is well connected, it can supply power to the thermostat. At this time, the display screen displays the ambient temperature.\u003cbr\u003eIndicator and nixie tube status description\u003cbr\u003eIndicator: Blinking indicates delay in starting cooling or heating. Steady on indicates that the relay is closed\u003cbr\u003eDigital tube: display LL for the sensor open circuit, please connect the sensor according to the instructions; If HH is out of the measuring range, the thermostat will disconnect the relay forcibly. Display -- high temperature alarm\u003cbr\u003eParameter Function Description\u003cbr\u003eLong press SET for 5 seconds to enter the main menu setting, press +- to switch to P0... P6, long press SET or 10 seconds no key action controller automatically confirm return.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eP0 cooling and heating mode\u003cbr\u003eLong press SET for 5 seconds to display P0, press SET once to SET the working mode, press +- to switch [H for heating mode] [C for cooling mode], press SET once to return, long press Set or 10 seconds without key action the controller will automatically confirm completion.\u003cbr\u003eRefrigeration mode: when the temperature measurement value is greater than or equal to the temperature setting point, the refrigeration relay draws, and the refrigerator starts; When the temperature measurement value is less than the temperature setting point-return difference, the refrigeration relay is disconnected and the refrigerator is closed.\u003cbr\u003eHeating mode: When the temperature measurement value is less than the temperature setting point, the heating relay draws and the heater starts; When the temperature measurement value is greater than or equal to the temperature setting point + return difference, the heating relay is disconnected and the heater is closed.\u003cbr\u003e\u003cbr\u003eP1 back error setting\u003cbr\u003ePress +- to switch to P1. Press SET once to SET the return difference value. Press +- to SET the return difference value to 0.1-15.\u003cbr\u003eRefrigeration mode: when the temperature measurement value is greater than or equal to the set value, the relay suction, the refrigerator starts; When the temperature measurement value is less than the set value - return value, the relay is disconnected and the cooler is closed.\u003cbr\u003eFor example, when the environment is 30¡æ, the set value is 25¡æ, and the return difference is 2¡æ. After power on, the closed refrigerator of the relay starts. When the refrigeration reaches 23¡æ, the refrigerator of the relay will be disconnected and shut down.\u003cbr\u003eHeating mode: when the temperature measurement value ¡Ü set value, relay suction, heater start; When the temperature measurement value is not less than the set value + return value, the relay is disconnected and the heater is closed.\u003cbr\u003eFor example, when the environment is 10¡æ, the set value is 25¡æ, and the return difference is 2¡æ. After power-up, the closed heater of the relay will start. When the heater is heated to 27¡æ, the relay will disconnect and the heater will close.\u003cbr\u003e\u003cbr\u003eP2 Set the upper limit for the maximum temperature\u003cbr\u003eIn order to avoid the danger of oversetting the temperature due to misoperation by others, the thermostat has the maximum setting upper limit function, which limits the setting range of the maximum temperature setting point controlled by the thermostat.\u003cbr\u003ePress +- to switch to P2. Press SET once to SET the maximum limit. Press +- to SET the maximum temperature that can be SET.\u003cbr\u003eFor example, if the temperature setting point is set to 60, the maximum temperature setting point can only be set to 60 ¡ã C. To expand the temperature range, you need to adjust the upper limit first.\u003cbr\u003e\u003cbr\u003eP3 Setting the Lower limit for the lowest temperature\u003cbr\u003eIn order to avoid the ice jam caused by the misoperation of others, the thermostat has the function of setting the minimum upper limit and lower limit, which limits the setting range of the setting point of the lowest temperature controlled by the thermostat.\u003cbr\u003ePress +- to switch to P3. Press SET once to SET the lowest limit. Press +- to SET the lowest temperature that can be SET.\u003cbr\u003eFor example, if the temperature setting point is set to 2, the minimum temperature setting point can be set to 2 ¡ã C. To expand the temperature range, you need to adjust the lower limit first.\u003cbr\u003e\u003cbr\u003eP4 Temperature correction\u003cbr\u003eWhen there is deviation between the measured temperature and the standard temperature or due to the special needs of the user's hardware, this function can be used to correct the temperature after correction = the temperature before correction + the effective range of correction is -7.0~7.0.\u003cbr\u003ePress +- to switch to P4. Press SET once for correction. Press +- to SET the correction value. Press SET once to return after completion.\u003cbr\u003eFor example, the normal value is 25 degrees. Display 25 degrees when the temperature correction is 0; Display 26.5 degrees when the temperature correction is 1.5; Display 23.5 when temperature correction is -1.5.\u003cbr\u003e\u003cbr\u003eP5 Delayed start time (unit: minute)\u003cbr\u003eWhen the refrigerator or heater has a delay function, the delay function can be enabled to protect the service life of the equipment.\u003cbr\u003ePress +- to switch to P5. Press SET once to SET the delayed start time unit as minutes. Press +- to SET 0-10 minutes\u003cbr\u003eCooling mode: When the first power is on, if the current temperature is greater than or equal to the set value, the cooler will not start cooling immediately. It needs to start after running the set delay time.\u003cbr\u003eHeating mode: For the first time, if the current temperature is less than the set value, the heater will not start heating immediately, and it needs to run the set delay time to start.\u003cbr\u003eWhen the downtime between two adjacent starts of the chiller or heater is greater than the set value of the delayed start time, the chiller starts immediately.\u003cbr\u003eWhen the stop interval between two adjacent starts of the cooler or heater is less than the set value of the delayed start time, the equipment can be started only after the refrigeration delay start time is completed. The delay time is calculated from the moment of shutdown.\u003cbr\u003eFor example, in the refrigeration state, the delay is set to 5 minutes, and the chiller starts the delay after the machine is turned on. When the chiller starts up after 5 minutes, the chiller stops when the required temperature is reached, and the timing starts at this time. When the next chiller starts the timing, it will work immediately.\u003cbr\u003eIf delay start is set to 0, the delay function is disabled.\u003cbr\u003eHow to Save Settings\u003cbr\u003eTo save the set data, set P7 to ON when the power is on after setting the temperature. In this way, the last setting will be kept when the power is off.\u003cbr\u003e\u003cbr\u003eP8 factory data reset\u003cbr\u003eDue to some human reasons, the internal Settings of the thermostat are confused, and it takes a lot of time to set one item by one. At this time, this function can be used to restore factory Settings. The specific method is: in the shutdown state, press and hold the + and - buttons at the same time, and then start up, and all the above parameters will be restored to factory Settings.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eFrequently Asked Questions (FAQ)\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eQ1: What Should I Do If I Receive A Damaged Item?\u003cbr\u003eA1: Please Contact Us Within 7 Days Of Receiving The Package, And We Will Provide A Solution.\u003cbr\u003eQ2: How Can I Contact Customer Service?\u003cbr\u003eA2: You Can Reach Us Through The AliExpress Messaging System, And Our Customer Service Team Will Respond During Business Days.\u003cbr\u003eQ3: How Important Is Feedback To You?\u003cbr\u003eA3: Your Feedback Is Crucial To Our Development, And We Sincerely Invite Satisfied Customers To Leave Positive Reviews.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sfbc518e390764cb0bbf08f06f648df31g.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eFeedback \u0026amp; Reviews\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eWe Appreciate Your Timely Confirmation Upon Receiving Your Order.\u003cbr\u003eYour Feedback Is Vital To Us; If You Are Satisfied With Our Product And Service, Please Leave Positive Feedback. This Will Greatly Help Us.\u003cbr\u003ePlease Contact Us Before Leaving Any Negative Or Neutral Feedback.\u003cbr\u003eWe Will Work Hard To Resolve Any Issues You May Have. Thank You For Your Understanding!\u003c\/p\u003e\n\u003c\/div\u003e\u003cbr\u003e","brand":"Keszoox","offers":[{"title":"AC 110-220V \/ CHINA","offer_id":46978927689963,"sku":"14:351074#AC 110-220V;200007763:201336100","price":7.8,"currency_code":"USD","in_stock":true},{"title":"DC 24V \/ CHINA","offer_id":46978927722731,"sku":"14:350852#DC 24V;200007763:201336100","price":6.68,"currency_code":"USD","in_stock":true},{"title":"DC 12V \/ CHINA","offer_id":46978927755499,"sku":"14:1202#DC 12V;200007763:201336100","price":6.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0677\/1005\/8731\/files\/digital-led-temperature-controller-w3230-thermostat-probe-heating-cooling.webp?v=1761026188","url":"https:\/\/keszooxstore.com\/products\/digital-led-temperature-controller-w3230-high-precision-thermostat-with-probe-for-heating-and-cooling-dc-12v-24v-ac-110-220v","provider":"Keszoox","version":"1.0","type":"link"}