{"product_id":"solid-state-ac-relay-module-5v-x-2","title":"Solid State AC Relay Module 5V x 2","description":"\u003cp\u003e\u003cspan\u003e5V logic compatible, controls 100-240VAC@2A\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eDESCRIPTION\u003c\/h2\u003e\n\u003cp\u003eThe solid state relay module has 2 independent 5V logic compatible relays that can control up to 120\/240VAC@2A\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003ePACKAGE INCLUDES:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSolid State Relay Module 5V x 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKEY FEATURES OF SOLID STATE RELAY MODULE 5V X 2:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2 independently controlled SSR relays\u003c\/li\u003e\n\u003cli\u003ePhototriac coupler input isolation\u003c\/li\u003e\n\u003cli\u003eSwitch 100-240VAC @ 2A per relay\u003c\/li\u003e\n\u003cli\u003eLED indicators when relays are energized\u003c\/li\u003e\n\u003cli\u003eBuilt-in snubber circuit\u003c\/li\u003e\n\u003cli\u003eZero cross control\u003c\/li\u003e\n\u003cli\u003eActive LOW control inputs\u003c\/li\u003e\n\u003cli\u003e5V logic compatible, marginally 3.3V compatible.  See notes below\u003c\/li\u003e\n\u003cli\u003e5V operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSolid State Relay (SSR) modules are handy for controlling smaller AC loads.\u003c\/p\u003e\n\u003cp\u003eThis module switches up to 2 channels of AC at up to 2A per channel.  The solid state relays can turn each AC channel ON or OFF, but it cannot be used for dimming.\u003c\/p\u003e\n\u003cp\u003eCompared to a standard electro-mechanical relay, the solid state relay switches quicker and does not have the long-term mechanical reliability concerns of a standard relay as long as the maximum current limits are observed.  The main downside is that it cannot be used to control DC power and max current is limited to 2A.\u003c\/p\u003e\n\u003ch3\u003eModule Control\u003c\/h3\u003e\n\u003cp\u003eThese modules are 5V logic compatible and marginally 3.3V logic compatible.  The reason it is marginally 3.3V compatible is that to turn the relay output off with a logic HIGH, the input must be driven to a minimum of about 3.1V if Vcc is 5V.  A 3.3V MCU output may or may not get high enough, though pull-ups on the MCU output will help.  If Vcc is less than 5V, then the logic HIGH voltage required to fully turn the relay off will also be less.\u003c\/p\u003e\n\u003cp\u003eThe inputs have a relay driver transistor which means the device needs \u0026lt; 1 mA on the logic control pin to drive it.  If you have a microcontroller like an Arduino, you can drive the relays using any of the digital output pins.  The relays can also be controlled with mechanical switches or appropriate sensors.\u003c\/p\u003e\n\u003cp\u003eThe relays are activated with a logic\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eLOW\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003esignal.  There is a red LED that is lit when the control pin for that relay is driven low to activate the relay.  A logic\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eHIGH\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003edeactivates the relay and the LED will go off.\u003c\/p\u003e\n\u003ch3\u003eOpto-Isolation\u003c\/h3\u003e\n\u003cp\u003eThe relays have built-in phototriac couplers on their logic inputs.\u003c\/p\u003e\n\u003cp\u003eThese phototriac couplers provide electrical isolation between the logic control input and the relay power as an added layer of protection in case of a major failure on the AC load of the relay.\u003c\/p\u003e\n\u003ch3\u003eModule Power\u003c\/h3\u003e\n\u003cp\u003eThe module requires 4-6V power and ground to operate.  The ground must be common with the MCU for the control inputs to work.\u003c\/p\u003e\n\u003cp\u003eThe input has a reverse polarity protection diode in case the power connections are accidentally reversed.\u003c\/p\u003e\n\u003cp\u003eWhen a relay is energized, the relay draws about 10mA from the Vcc pin.  With both relays energized, the total draw is about 20mA.\u003c\/p\u003e\n\u003ch3\u003eRelay Operation\u003c\/h3\u003e\n\u003cp\u003eThe output of the relay is rated to switch AC power over a maximum range of 75VAC to 264VAC at 2A and suggested range of 100V to 240VAC.\u003c\/p\u003e\n\u003cp\u003eThe output is SPST type and is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNO\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Normally Open).  A logic\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eLOW\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eenergizes the relay, so the two output terminals are shorted and power passes through the relay.  A logic\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eHIGH\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(or no connection) de-energizes the relay and the output terminals are open.  As noted above, the logic high level needs to reach about 3.1V to fully shut the relay off when Vcc is 5V.\u003c\/p\u003e\n\u003cp\u003eThe relay operates at the zero cross point of the AC waveform so can switch every half cycle or 8.3mS.\u003c\/p\u003e\n\u003cp\u003eEach relay has a 2A soldered in fuse on the AC side for over-current protection.\u003c\/p\u003e\n\u003cdiv id=\"attachment_10652\" class=\"wp-caption aligncenter\"\u003e\n\u003cimg decoding=\"async\" aria-describedby=\"caption-attachment-10652\" class=\"wp-image-10652 size-full entered lazyloaded\" src=\"https:\/\/protosupplies.com\/wp-content\/uploads\/2021\/02\/SSR-Active-Low-Schematic.jpg\" alt=\"SSR Active Low Schematic\" width=\"629\" height=\"203\" data-lazy-srcset=\"https:\/\/protosupplies.com\/wp-content\/uploads\/2021\/02\/SSR-Active-Low-Schematic.jpg 629w, https:\/\/protosupplies.com\/wp-content\/uploads\/2021\/02\/SSR-Active-Low-Schematic-300x97.jpg 300w, https:\/\/protosupplies.com\/wp-content\/uploads\/2021\/02\/SSR-Active-Low-Schematic-280x90.jpg 280w, https:\/\/protosupplies.com\/wp-content\/uploads\/2021\/02\/SSR-Active-Low-Schematic-400x129.jpg 400w\" data-lazy-sizes=\"(max-width: 629px) 100vw, 629px\" data-lazy-src=\"https:\/\/protosupplies.com\/wp-content\/uploads\/2021\/02\/SSR-Active-Low-Schematic.jpg\" data-ll-status=\"loaded\" sizes=\"(max-width: 629px) 100vw, 629px\" srcset=\"https:\/\/protosupplies.com\/wp-content\/uploads\/2021\/02\/SSR-Active-Low-Schematic.jpg 629w, https:\/\/protosupplies.com\/wp-content\/uploads\/2021\/02\/SSR-Active-Low-Schematic-300x97.jpg 300w, https:\/\/protosupplies.com\/wp-content\/uploads\/2021\/02\/SSR-Active-Low-Schematic-280x90.jpg 280w, https:\/\/protosupplies.com\/wp-content\/uploads\/2021\/02\/SSR-Active-Low-Schematic-400x129.jpg 400w\"\u003e\n\u003cp id=\"caption-attachment-10652\" class=\"wp-caption-text\"\u003eSSR Active Low Schematic\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eModule Connections\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1 x 4 Screw Terminal Block\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDC+\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e= 4-6VDC (5V typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDC-\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e= Ground from MCU or other control input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Relay control input 1.  Logic HIGH level energizes relay 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Relay control input 2.  Logic HIGH level energizes relay 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Contacts (2 screw terminal blocks)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-polarized\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= AC input side of hot lead (typically black wire) connects to one side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-polarized\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Load side of hot lead connects to the other side.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eOUR EVALUATION RESULTS:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThese are nice relatively inexpensive modules that will work for a number of applications where lower power AC devices of up to about 220W @ 110V need to be controlled.  For a terrarium setup for instance, the module could automatically control the lights, heat lamp, heat rock, mister, circulating fan and similar devices.  Control of Christmas lighting is another popular type of application.\u003c\/p\u003e\n\u003cp\u003eWhen switching AC power, proper safety should be observed to ensure the wiring is secure and not easily contacted to avoid an electrical shock.  These are often built into a electrical box with a terminal strip to make the AC electrical connections in a safe and secure manner.\u003c\/p\u003e\n\u003cp\u003eNote that unlike mechanical relays, SSR relays cannot be operated in parallel to increase their current handling capability. This is because the relays will not turn on at exactly the same time and the first one to turn on will carry the full load until it fails or the fuse blows and then the second one will turn on and also subsequently fail.\u003c\/p\u003e\n\u003cp\u003eFor redundancy purposes, it is possible to operate 2 is parallel if the load is within the 2A limit of a single relay. If the relay carrying the load fails, the other relay will automatically switch on.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eBEFORE THEY ARE SHIPPED, THESE MODULES ARE:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSample inspected and tested per incoming shipment.\u003c\/li\u003e\n\u003cli\u003eRepackaged in high quality resealable ESD bag for safe storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFURTHER READING:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ia.omron.com\/support\/guide\/18\/introduction.html\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan\u003e\u003cstrong\u003eOmron SSR Technical Guide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/makezine.com\/projects\/arduino-relays-high-voltage\/\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan\u003e\u003cstrong\u003eExample application – Great Houdini Escape Room\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNotes: \u003c\/em\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\u003ci\u003eNone\u003c\/i\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003ctable class=\"table table-hover\" width=\"989\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"145\"\u003e\u003cstrong\u003eLogic Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"264\"\u003e\u003c\/td\u003e\n\u003ctd width=\"229\"\u003e+5 Logic Compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"145\"\u003e\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eLogic High\u003c\/td\u003e\n\u003ctd width=\"229\"\u003e\u0026gt; 3.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"145\"\u003e\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eUnknown State\u003c\/td\u003e\n\u003ctd width=\"229\"\u003e 2.0V –  3.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"145\"\u003e\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eLogic Low\u003c\/td\u003e\n\u003ctd width=\"229\"\u003e\u0026lt; 2.0V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"145\"\u003e\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eDrive Current\u003c\/td\u003e\n\u003ctd width=\"229\"\u003e\u0026lt; 1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"145\"\u003e \u003cstrong\u003eVcc\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eVoltage Range\u003c\/td\u003e\n\u003ctd width=\"229\"\u003e4-6VDC (5V typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"145\"\u003e\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eMaximum Current\u003c\/td\u003e\n\u003ctd width=\"229\"\u003e10mA per relay, 40mA with all relays energized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"145\"\u003e\u003cstrong\u003eRelay Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eMaximum\u003c\/td\u003e\n\u003ctd width=\"229\"\u003e75-264VAC @ (0.1 – 2A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"145\"\u003e\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eRecommended\u003c\/td\u003e\n\u003ctd width=\"229\"\u003e100-240VAC @ (0.1 – 2A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"145\"\u003e\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eMax Inrush Current\u003c\/td\u003e\n\u003ctd width=\"229\"\u003e 30A (8.3mS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"145\"\u003e\u003cstrong\u003eRelay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eOmron\u003c\/td\u003e\n\u003ctd width=\"229\"\u003eG3MB-202P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"145\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eL x W x H\u003c\/td\u003e\n\u003ctd width=\"229\"\u003e55 x 33 x 25mm (2.16 x 1.3 x 1″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!----\u003e","brand":"Keszoox","offers":[{"title":"Default Title","offer_id":45681479811307,"sku":"","price":17.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0677\/1005\/8731\/files\/Solid-State-Relay-Module-2-x-5V.jpg?v=1723005843","url":"https:\/\/keszooxstore.com\/products\/solid-state-ac-relay-module-5v-x-2","provider":"Keszoox","version":"1.0","type":"link"}