{"product_id":"xh-m131-light-control-photoresistor-relay-module-5v-12v-24v-automatic-brightness-detection-switch-10a","title":"XH-M131 Light Control Photoresistor Relay Module 5V\/12V\/24V Automatic Brightness Detection Switch 10A","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eApplication\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eComputer\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eKeszoox\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCondition\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNew\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel Number\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eXH-M131\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e-20+50\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e5V \/ 12V \/ 24V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eRelay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_dynamic\"\u003e\u003ckse:widget data-widget-type=\"relatedProduct\" id=\"1005000012654807\" title=\"\" type=\"relation\"\u003e\u003c\/kse:widget\u003e\u003c\/div\u003e\r\n\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-size:20px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eXH-M131 DC 5V 12V 24V Light Control Switch Photoresistor Relay Module Detection Sensor \u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003e10A \u003c\/strong\u003e\u003c\/span\u003eBrightness Automatic Control Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e \u003cbr\u003e \u003cspan style=\"font-size:16px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eThis module can be used for light detection and brightness detection. It has a power indicator (red) and a relay pull in indicator (blue), and is equipped with four M3 screw mounting holes, which greatly facilitates installation. The board can adjust the photosensitivity through a potentiometer. It has a relay, which can be used as a variety of brightness detection control switches, such as street lamps, which can be automatically turned on at night, turned off at day, and other equipment that needs automation.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cbr\u003e \u003cbr\u003e Input: DC 5V \/ 12V\u003cbr\u003e Load capacity: 10A \/ AC 250V or DC up to 30V\u003cbr\u003e RED LED ON: Indicate the Power ON\u003cbr\u003e BLUE LED ON: Relay is working\u003cbr\u003e Module output terminal has three ports\u003cbr\u003e Normally open ( NO )\u003cbr\u003e Common terminal ( COM )\u003cbr\u003e Normally closed ( NC )\u003cbr\u003e Size: 53*31*19mm\u003cbr\u003e Light threshold can be adjusted by potentiometer to set the relay start\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eParameters:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1. The module adopts 12V power supply, with anti reverse connection function, and the reverse connection power will not damage the module;\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e2. Large load capacity of normally open interface: AC 0V-125V\/20A, DC 0V-14V\/20A; The output end of the module has three ports: common end (COM), normally open (CK) and normally closed (CB). The three ports are equivalent to a dual control switch. When the relay coil is powered, the common end is connected to the normally open end. When there is no power, the common end is connected to the normally closed end. The COM end is generally connected to the negative power supply through the load, and the normally open end is connected to the positive power supply.\u003cbr\u003e 3. The sensitivity can be adjusted through the potentiometer, and the threshold value of the starting relay can be set by adjusting the potentiometer. When the light is darker than the threshold value, the module relay is pulled in, and when the light is brighter than the threshold value, the relay is disconnected;\u003c\/span\u003e\u003c\/span\u003e\n \u003cbr\u003e  \n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eInstructions:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1. The photoresist module is most sensitive to the brightness of the ambient light, and is generally used to detect the brightness change of the ambient light.\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e2. When the ambient light of the module is darker than the threshold value, the relay is pulled in, and the common end is connected with the normally closed end (disconnected from the normally closed end). When the external ambient light is brighter than the set threshold value, the relay is disconnected, and the common end is disconnected from the normally closed end (disconnected from the normally closed end)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e3. Common terminal, normally open, normally closed, the three ports are equivalent to a double control switch. When the relay coil is energized, the common terminal is connected with the normally open terminal, and when there is no power, the common terminal is connected with the normally closed terminal.\u003c\/span\u003e\u003c\/span\u003e\n \u003cbr\u003e  \n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eDescription of Potentiometer Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eRed light: module working voltage,\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eBlue light: relay working indicator\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003ePotentiometer: adjust detection brightness value\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eInstallation wiring (take the control of street lamps as an example)\u003c\/span\u003e\u003c\/span\u003e\n \u003cbr\u003e  \n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMatters Needs Attention:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e \n\u003cdiv\u003e\n \u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1. If you need to work at night and do not work during the day, please connect the common terminal and the normally open terminal, such as street lamp control. Otherwise, connect the common terminal and the normally closed terminal. (Please select port wiring according to actual needs)\u003cbr\u003e 2. One contact in the middle of the output terminal is the normally closed terminal below the common terminal, and the upper one is the normally open terminal.\u003cbr\u003e \u003cimg referrerpolicy=\"no-referrer\" src=\"https:\/\/ae01.alicdn.com\/kf\/S6bd3d53f8dee4714b8ef0f7464e8a6bb2.jpg\"\u003e\u003cimg referrerpolicy=\"no-referrer\" src=\"https:\/\/ae01.alicdn.com\/kf\/S92d499ee82694241b6afb3245a4dc14cB.jpg\"\u003e\u003cimg referrerpolicy=\"no-referrer\" src=\"https:\/\/ae01.alicdn.com\/kf\/S0ad4e102582e48899ec56e67e5462289s.jpg\"\u003e\u003cimg referrerpolicy=\"no-referrer\" src=\"https:\/\/ae01.alicdn.com\/kf\/S34bee79c06f4441d8ea934de06360d83V.jpg\"\u003e\u003cimg referrerpolicy=\"no-referrer\" src=\"https:\/\/ae01.alicdn.com\/kf\/S828fceff070f4cb995c526f8567735ad6.jpg\"\u003e\u003cimg referrerpolicy=\"no-referrer\" src=\"https:\/\/ae01.alicdn.com\/kf\/S07783cec394543a2a56fd16057d56dc07.jpg\"\u003e\u003cimg referrerpolicy=\"no-referrer\" src=\"https:\/\/ae01.alicdn.com\/kf\/S5d20a68949d1462a8115335f6d3f77e19.jpg\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\r\n","brand":"Keszoox","offers":[{"title":"5V","offer_id":46981893914859,"sku":"14:350852#5V","price":5.72,"currency_code":"USD","in_stock":true},{"title":"12V","offer_id":46981893947627,"sku":"14:350850#12V","price":5.72,"currency_code":"USD","in_stock":true},{"title":"24V","offer_id":46981893980395,"sku":"14:200000195#24V","price":5.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0677\/1005\/8731\/files\/xh-m131-light-control-photoresistor-relay-module.webp?v=1761113086","url":"https:\/\/keszooxstore.com\/products\/xh-m131-light-control-photoresistor-relay-module-5v-12v-24v-automatic-brightness-detection-switch-10a","provider":"Keszoox","version":"1.0","type":"link"}